Inflection Point Engineering Reference Tables

IEC 60079 Hazardous Area Codes

Gas groups, temperature classes, zone definitions, and equipment protection level (EPL) mapping per IEC 60079 series.

Zone Classifications

IEC Zone NEC/CEC Equivalent Definition (IEC 60079-10-1) Typical Example Reference
Zone 0 Class I Div 1 (continuous) Explosive gas atmosphere is present continuously or for long periods Inside fuel tank vapor space IEC 60079-10-1:2020 Sec 6
Zone 1 Class I Div 1 (intermittent) Explosive gas atmosphere is likely to occur in normal operation occasionally Around vents, sample points, pump seals IEC 60079-10-1:2020 Sec 6
Zone 2 Class I Div 2 Explosive gas atmosphere is not likely to occur in normal operation; if it does, only briefly General process areas with closed equipment IEC 60079-10-1:2020 Sec 6
Zone 20 Class II Div 1 (continuous) Combustible dust is present continuously or for long periods Interior of dust collector, hopper IEC 60079-10-2:2015
Zone 21 Class II Div 1 (intermittent) Combustible dust is likely to occur in normal operation occasionally Adjacent to dust filter charge points IEC 60079-10-2:2015
Zone 22 Class II Div 2 Combustible dust is not likely to occur in normal operation General areas around dust-handling equipment IEC 60079-10-2:2015

Gas Groups

IEC Group NEC Group Representative Gas MESG (mm) MIC Ratio Reference
IIA D Methane / Propane >0.90 >0.80 IEC 60079-20-1:2017
IIB C Ethylene 0.50-0.90 0.45-0.80 IEC 60079-20-1:2017
IIB+H2 C+H2 Hydrogen-mix special as IIB as IIB IEC 60079-20-1:2017
IIC A/B Hydrogen / Acetylene <0.50 <0.45 IEC 60079-20-1:2017
I MSHA Methane (mining) for mining apps - IEC 60079-0:2017
IIIA E (fibers) Combustible flyings - - IEC 60079-0:2017
IIIB F (dust) Non-conductive dust - - IEC 60079-0:2017
IIIC G (dust) Conductive dust - - IEC 60079-0:2017

Temperature Classes

T-Class Max Surface Temp deg C Max Surface Temp deg F Note Reference
T1 450 842 Most flexible; covers most hydrocarbons IEC 60079-0:2017
T2 300 572 Below H2 AIT; many service fluids IEC 60079-0:2017
T3 200 392 Below diesel AIT (~210C) IEC 60079-0:2017
T4 135 275 Below H2S AIT (~270C); below ether AIT IEC 60079-0:2017
T5 100 212 Specialty - low-AIT solvents IEC 60079-0:2017
T6 85 185 CS2 / very low AIT services IEC 60079-0:2017

Protection Methods

Code Method Name IEC Standard Permissible Zones Description
Ex d Flameproof enclosure IEC 60079-1 1, 2 Contains internal explosion; flame-resistant joints
Ex e Increased safety IEC 60079-7 1, 2 No arcing/sparking parts; higher creepage and clearance
Ex i Intrinsic safety IEC 60079-11 0 (ia), 1 (ib), 2 (ic) Energy/temperature limited; safest for instruments
Ex p Pressurized enclosure IEC 60079-2 1 (px), 2 (py/pz) Inert gas purge maintains positive pressure
Ex m Encapsulation IEC 60079-18 0 (ma), 1 (mb), 2 (mc) Components encased in compound
Ex n Non-incendive IEC 60079-15 2 Non-sparking, restricted breathing
Ex o Oil immersion IEC 60079-6 2 Components submerged in oil
Ex q Powder filling IEC 60079-5 2 Sand-filled enclosure
Ex t Dust ignition protection IEC 60079-31 20 (ta), 21 (tb), 22 (tc) Dust-tight enclosure with limited surface temp
Ex op Optical radiation IEC 60079-28 0 (op is), 1 (op pr), 2 (op sh) Inherently safe / protected / shielded optical

Notes

Source: IEC_60079_Hazardous_Area_Codes_v1.xlsx