Section 5 — Piping
IPE Engineering Practice IPE-EP-5-3-15DS
Document number: IPE-EP-5-3-15DS · Section: 5 — Piping
1. Item Number 3. Service, Line, or Equip. No. 2. Tag Number 4. Design Code or Standard Service Conditions (include applicable units) 5. Vessel or Piping MAWP 6. Fluid 7. Fluid State (initiating rupture) 8. Fluid State (relieving conditions) 9. Required Relieving Capacity 10. Molecular Weight or Specific Gravity 11. Viscosity at Relieving Temperature 12. Compressibility Factor (Z) 13. Specific Heat Ratio 14. Normal Maximum Operating Pressure 15. Normal Maximum Operating Temperature 16. Pressure Fluctuations (static, cyclic, pulsating) 17. Superimposed Back Pressure 18. Built-up Back Pressure 19. Back Pressure 20. Inlet Vacuum Conditions 21. Outlet Vacuum Conditions 22. Disk Located Upstream of Valve (yes/no) 23. Disk Located Downstream of Valve (yes/no) 24. Non Fragmenting Design (yes/no) Connections 25. Nominal Pipe Size 27. Flange Face (inlet/outlet) 26. Flange Standard & Class 28. Piping Schedule or Bore Rupture Disk Holder Rupture Disk 29. Holder Tag No. 41. Nominal Disk Size 30. Nominal Holder Size 42. Disk Type 31. Design Type 43. Model Designator 32. Model Designator 44. Quantity Required 33. Quantity Required 45. Manufacturing Range 34. Holder Material (inlet) 46. Specified Burst Temperature 35. Holder Material (outlet) 47. Specified Burst Pressure 36. Gage Tap (yes/no) & Size 48. Max Marked Burst Pressure
| RUPTURE DISK DEVICE SPECIFICATION | Sheet No. Page 1 of 2 | |||
|---|---|---|---|---|
| Requisition No. | ||||
| Job No. | ||||
| Date | ||||
| Revised | ||||
| By | ||||
| General | ||||
| 1. | Item Number | 3. | Service, Line, or Equip. No. | |
| 2. | Tag Number | 4. | Design Code or Standard | |
| Service Conditions (include applicable units) | ||||
| 5. | Vessel or Piping MAWP | |||
| 6. | Fluid | |||
| 7. | Fluid State (initiating rupture) | |||
| 8. | Fluid State (relieving conditions) | |||
| 9. | Required Relieving Capacity | |||
| 10. | Molecular Weight or Specific Gravity | |||
| 11. | Viscosity at Relieving Temperature | |||
| 12. | Compressibility Factor (Z) | |||
| 13. | Specific Heat Ratio | |||
| 14. | Normal Maximum Operating Pressure | |||
| 15. | Normal Maximum Operating Temperature | |||
| 16. | Pressure Fluctuations (static, cyclic, pulsating) | |||
| 17. | Superimposed Back Pressure | |||
| 18. | Built-up Back Pressure | |||
| 19. | Back Pressure | |||
| 20. | Inlet Vacuum Conditions | |||
| 21. | Outlet Vacuum Conditions | |||
| 22. | Disk Located Upstream of Valve (yes/no) | |||
| 23. | Disk Located Downstream of Valve (yes/no) | |||
| 24. | Non Fragmenting Design (yes/no) | |||
| Connections | ||||
| 25. | Nominal Pipe Size | 27. | Flange Face (inlet/outlet) | |
| 26. | Flange Standard & Class | 28. | Piping Schedule or Bore | |
| Rupture Disk Holder | Rupture Disk | |||
| 29. | Holder Tag No. | 41. | Nominal Disk Size | |
| 30. | Nominal Holder Size | 42. | Disk Type | |
| 31. | Design Type | 43. | Model Designator | |
| 32. | Model Designator | 44. | Quantity Required | |
| 33. | Quantity Required | 45. | Manufacturing Range | |
| 34. | Holder Material (inlet) | 46. | Specified Burst Temperature | |
| 35. | Holder Material (outlet) | 47. | Specified Burst Pressure | |
| 36. | Gage Tap (yes/no) & Size | 48. | Max Marked Burst Pressure |
CoInafsletcatilo nA Prouinbta E nEgningeeirninege Prriancgtic Pesractices Rupture Disk Devices Data Sheet Accessories 49. Min Marked Burst Pressure 37. Studs & Nuts (y/n) & Matl 50. Operating Ratio 38. Jackscrews (yes/no) 51. Max Flow Resistance K R 39. Telltale Assy (y/n) & Matl 52. Rupture Disk Materials 40. Other 53. Manufacturer's Data
| Accessories | 49. | Min Marked Burst Pressure | |||
|---|---|---|---|---|---|
| 37. | Studs & Nuts (y/n) & Matl | 50. | Operating Ratio | ||
| 38. | Jackscrews (yes/no) | 51. | Max Flow Resistance K R |
||
| 39. | Telltale Assy (y/n) & Matl | 52. | Rupture Disk Materials | ||
| 40. | Other | ||||
| 53. | Manufacturer's Data | ||||
© 2026 Inflection Point Engineering, LLC. All rights reserved. The content of this page — including calculation methods, reference data, written analysis, interactive tools, and source code — is the intellectual property of Inflection Point Engineering, LLC and is protected under applicable copyright, trademark, and trade secret laws. Unauthorized reproduction, redistribution, modification, or derivative use in whole or in part is prohibited without prior written consent.
Disclaimer. This material is provided for informational and educational purposes only and does not constitute professional engineering advice. Calculations, reference data, and methodologies are based on published standards and accepted engineering practice but are not a substitute for engineering judgment, site-specific analysis, or review by a licensed Professional Engineer. Inflection Point Engineering, LLC makes no warranties, express or implied, regarding the accuracy, completeness, or fitness for a particular purpose of any content presented here, and shall not be liable for any direct, indirect, incidental, or consequential damages arising from its use. Users assume all risk associated with applying this content to real-world design, operations, or decisions.