Level Instruments

Chapter from the Vessels & Internals Design Guide.

NAVIGATION

Design P&T Selection Vessel Sizing Nozzle Sizing Level Instruments
Vacuum Vessels Ceramic Balls Reference Data

Level Instrument Sizing

Instrument Type Accuracy (%) Best For Installation Notes
Float Switch ±2 Alarm/Control 45° minimum nozzle angle
Capacitive Probe ±1 Continuous Avoid foam/mist areas
Differential Pressure ±0.5 Exact Level Calibrate for density
Guided Wave Radar ±0.1 High Accuracy Needs dry nozzle
Displacer ±0.5 Interface Level Use for density variation

Installation Requirements:

• Minimum 12" from vessel centerline for level glass

• Isolation ball valves on both connections (safety)

• Sediment trap at lower connection

• Air vent at upper connection for DP cells

Source: Vessels_Internals_Design_Guide_v1.xlsx · sheet “Level Instruments”