Pumps & Hydraulics Design Guide
Chapter from the Pumps & Hydraulics Design Guide.
| Type | Configuration | Typical Flow (GPM) | Max Head (ft) | Typical Service | Advantages | Limitations | Common Applications |
|---|---|---|---|---|---|---|---|
| OH1 | Overhung, foot-mounted | 10–2,000 | 600 | Light duty | Low cost, simple | Foot alignment sensitive | Chemical feed, utility water |
| OH2 | Overhung, centerline-mounted | 10–5,000 | 800 | Hot service (>250°F) | Thermal growth handled | Higher cost than OH1 | Hot oil, reflux, charge pumps |
| OH3 | Overhung, close-coupled | 5–500 | 300 | Low flow | No coupling, compact | Motor bearing loads | Seal flush, small chemical |
| BB1 | Between bearings, axial split | 100–20,000 | 600 | High flow, low head | Easy maintenance | Not for high pressure H2 | Cooling water, crude charge |
| BB2 | Between bearings, radial split | 50–10,000 | 3,000 | High pressure | Handles high P | More complex maintenance | BFW, high-P hydrocarbon |
| BB3 | Between bearings, multistage axial | 100–15,000 | 2,000 | Multistage | High head capability | Axial thrust management | Pipeline, multistage BFW |
| BB5 | Between bearings, multistage radial | 50–8,000 | 6,000+ | Very high pressure | Highest heads available | Complex, expensive | High-P injection, boiler feed |
| VS1 | Vertical, single stage | 10–5,000 | 200 | Sump service | Below-grade suction | Bearing access difficult | Sump pumps, drainage |
| VS6 | Vertical, multistage (can) | 50–3,000 | 5,000 | Low NPSHA | Very low NPSH required | Expensive, long lead | Condensate, LPG, cryogenic |
| Parameter | OH1/OH2 | BB1 | BB2/BB5 | VS6 | Key Decision Factor |
|---|---|---|---|---|---|
| Temperature | <250°F: OH1 >250°F: OH2 | Ambient–300°F | Any | Cryogenic OK | Hot service → OH2 minimum |
| Suction Pressure | Low–moderate | Low–moderate | High | Low (submerged) | High P → radial split (BB2) |
| NPSH Available | Normal | Normal | Normal | Very low | Low NPSHA → VS6 or OH2 w/ inducer |
| Flow Range | Low–moderate | High | Moderate | Low–moderate | High flow → BB1 |
| Head Required | Low–moderate | Low | High–very high | High | High head → BB2/BB5 multistage |
| H2 Service | OK if low P | Avoid (axial split) | BB2 preferred | OK | H2 service → radial split mandatory |
• Minimum design life: 20 years, 3 years uninterrupted operation
• Preferred operating region: 80–110% of BEP flow
• Minimum continuous stable flow: per manufacturer curve, typically 50–60% BEP
• Rated point: must be within preferred operating region
• Maximum allowable working pressure: defined by casing pressure class
• Hydrotest pressure: 1.5× MAWP at ambient temperature
Source: Pumps_Hydraulics_Design_Guide_v1.xlsx · sheet “Pump Selection”
© 2026 Inflection Point Engineering, LLC. All rights reserved. The content of this page — including calculation methods, reference data, written analysis, interactive tools, and source code — is the intellectual property of Inflection Point Engineering, LLC and is protected under applicable copyright, trademark, and trade secret laws. Unauthorized reproduction, redistribution, modification, or derivative use in whole or in part is prohibited without prior written consent.
Disclaimer. This material is provided for informational and educational purposes only and does not constitute professional engineering advice. Calculations, reference data, and methodologies are based on published standards and accepted engineering practice but are not a substitute for engineering judgment, site-specific analysis, or review by a licensed Professional Engineer. Inflection Point Engineering, LLC makes no warranties, express or implied, regarding the accuracy, completeness, or fitness for a particular purpose of any content presented here, and shall not be liable for any direct, indirect, incidental, or consequential damages arising from its use. Users assume all risk associated with applying this content to real-world design, operations, or decisions.