Inflection Point Engineering Pumps & Hydraulics Design Guide

Pump Selection

Chapter from the Pumps & Hydraulics Design Guide.

CENTRIFUGAL PUMP SELECTION — API 610

API 610 Pump Type Classification

Type Configuration Typical Flow (GPM) Max Head (ft) Typical Service Advantages Limitations Common Applications
OH1 Overhung, foot-mounted 10–2,000 600 Light duty Low cost, simple Foot alignment sensitive Chemical feed, utility water
OH2 Overhung, centerline-mounted 10–5,000 800 Hot service (>250°F) Thermal growth handled Higher cost than OH1 Hot oil, reflux, charge pumps
OH3 Overhung, close-coupled 5–500 300 Low flow No coupling, compact Motor bearing loads Seal flush, small chemical
BB1 Between bearings, axial split 100–20,000 600 High flow, low head Easy maintenance Not for high pressure H2 Cooling water, crude charge
BB2 Between bearings, radial split 50–10,000 3,000 High pressure Handles high P More complex maintenance BFW, high-P hydrocarbon
BB3 Between bearings, multistage axial 100–15,000 2,000 Multistage High head capability Axial thrust management Pipeline, multistage BFW
BB5 Between bearings, multistage radial 50–8,000 6,000+ Very high pressure Highest heads available Complex, expensive High-P injection, boiler feed
VS1 Vertical, single stage 10–5,000 200 Sump service Below-grade suction Bearing access difficult Sump pumps, drainage
VS6 Vertical, multistage (can) 50–3,000 5,000 Low NPSHA Very low NPSH required Expensive, long lead Condensate, LPG, cryogenic

Pump Type Selection Decision Criteria

Parameter OH1/OH2 BB1 BB2/BB5 VS6 Key Decision Factor
Temperature <250°F: OH1 >250°F: OH2 Ambient–300°F Any Cryogenic OK Hot service → OH2 minimum
Suction Pressure Low–moderate Low–moderate High Low (submerged) High P → radial split (BB2)
NPSH Available Normal Normal Normal Very low Low NPSHA → VS6 or OH2 w/ inducer
Flow Range Low–moderate High Moderate Low–moderate High flow → BB1
Head Required Low–moderate Low High–very high High High head → BB2/BB5 multistage
H2 Service OK if low P Avoid (axial split) BB2 preferred OK H2 service → radial split mandatory

Key API 610 Requirements

• Minimum design life: 20 years, 3 years uninterrupted operation
• Preferred operating region: 80–110% of BEP flow
• Minimum continuous stable flow: per manufacturer curve, typically 50–60% BEP
• Rated point: must be within preferred operating region
• Maximum allowable working pressure: defined by casing pressure class
• Hydrotest pressure: 1.5× MAWP at ambient temperature

Source: Pumps_Hydraulics_Design_Guide_v1.xlsx · sheet “Pump Selection”