FCC Operations Guide
Chapter from the FCC Operations Guide.
| Problem | Symptoms | Likely Causes | Diagnostics | Corrective Actions | Safety Implications |
|---|---|---|---|---|---|
| Afterburn | Regen dilute temp > dense bed temp High cyclone temperatures | Incomplete combustion in dense bed CO burning in dilute phase | Compare dense vs. dilute temps Check O2 in flue gas | Increase excess O2 Add Pt combustion promoter Reduce feed rate | CRITICAL: cyclone damage, refractory failure |
| Catalyst losses | High stack opacity Low E-cat inventory Fines in slurry | Cyclone damage/erosion Attrition (high velocity) High fines in fresh cat | PSD analysis of E-cat Stack opacity monitor Cyclone ΔP trending | Inspect cyclones at T/A Reduce velocities Change catalyst supplier | Product contamination, environmental |
| Slide valve problems | Erratic temperatures Pressure balance instability Inability to control circulation | Erosion of valve/seat Coking/deposits Stem or actuator issues | Valve position vs. demand Stroking test Pressure surveys | Adjust valve tuning Plan repair at T/A Use bypass if available | Loss of circulation = emergency |
| Poor stripping | High coke yield (delta coke) High regen temperature High H/C ratio in coke | Insufficient steam Stripped plugging/maldistribution High catalyst circulation | H/C ratio of coke Stripping steam rate Spent catalyst temperature | Increase stripping steam Clean distributors at T/A Reduce circulation | Excess coke can exceed air/heat limits |
| Feed distribution issues | Uneven riser temperatures Low conversion at normal conditions High slurry yield | Plugged feed nozzles Low feed pressure Nozzle tip erosion | Riser TI profile Feed nozzle ΔP Nozzle inspection at T/A | Clean/replace nozzles Increase feed pressure Atomizing steam adjustment | Liquid carryover to regenerator |
| High regenerator pressure | Air blower at limit Restricted flue gas flow Surging | Flue gas slide valve restriction Cyclone plugging Orifice chamber fouling | Check flue gas valve position Regenator ΔP profile Blower surge margin | Open flue gas valve Reduce feed rate (less coke) Clean at turnaround | Blower surge = emergency |
Source: FCC_Operations_Guide_v1.xlsx · sheet “Troubleshooting”
© 2026 Inflection Point Engineering, LLC. All rights reserved. The content of this page — including calculation methods, reference data, written analysis, interactive tools, and source code — is the intellectual property of Inflection Point Engineering, LLC and is protected under applicable copyright, trademark, and trade secret laws. Unauthorized reproduction, redistribution, modification, or derivative use in whole or in part is prohibited without prior written consent.
Disclaimer. This material is provided for informational and educational purposes only and does not constitute professional engineering advice. Calculations, reference data, and methodologies are based on published standards and accepted engineering practice but are not a substitute for engineering judgment, site-specific analysis, or review by a licensed Professional Engineer. Inflection Point Engineering, LLC makes no warranties, express or implied, regarding the accuracy, completeness, or fitness for a particular purpose of any content presented here, and shall not be liable for any direct, indirect, incidental, or consequential damages arising from its use. Users assume all risk associated with applying this content to real-world design, operations, or decisions.