Inflection Point Engineering Structural and Civil Engineering Curriculum

Civil Sys

Module from the Structural and Civil Engineering Curriculum curriculum.

Module 10 - Civil Systems · Learning Objectives · 1. Design paved roads for H-20 loading per AASHTO · 2. Size stormwater drainage for 10-yr 24-hr storm (local) · 3. Separate oily water sewer (OWS) from sanitary from stormwater · 4. Specify chain-link fencing per IPE-EP-4-10-1 · 5. Apply ADA accessibility for office buildings per IPE-EP-4-6-2 · Sewer System Separation (API 2610)

System Flow Treatment Notes Typical Pipe Ref
Oily water sewer (OWS) Process drains, pump glands API separator + DAF Contaminated 8-12 in concrete or HDPE API 2610
Storm (rainwater) Paved and process areas Gravity to catch basin First-flush to OWS 12-24 in API 2610
Sanitary Office and wash rooms Septic or POTW Domestic only 6-8 in PVC Local code
Chemical (acid/caustic) Spot drains Neutralization Dedicated Fiberglass or specialty Special
Fire water Hydrants Storage + pumps Per NFPA 24 Ductile iron NFPA 24

Source: Structural_Civil_Engineering_Curriculum_v1.xlsx · Sheet: Civil Sys