Materials and Corrosion Curriculum
Module from the Materials and Corrosion Curriculum curriculum.
CORROSION UNDER INSULATION (CUI) · Learning Objectives · 1. Identify CUI susceptibility by temperature range and environment 2. Select appropriate inspection methods for insulated systems 3. Apply coating specifications and insulation quality standards 4. Prioritize inspections using risk-based methodology (API 581/583) · CUI Risk by Temperature and Environment
| Service Temperature | CUI Risk | Typical Environment | Inspection Priority | Coating Required? | Notes |
|---|---|---|---|---|---|
| <14°F | Low (frozen) | Cold service, LNG, cryogenic | Low | Yes — cold service coating | Moisture frozen, low reaction rate |
| 14-250°F | HIGH | Ambient-condensing zone | HIGHEST | Yes — CUI coating mandatory | Sweating, rain ingress, maximum risk zone |
| 250-350°F | Medium-High | Steam traced, moderate-temp services | High | Yes — high-temp coating | Alternate wet/dry cycling |
| 350-400°F | Medium | Hot service above boiling | Medium | Yes | Water mostly evaporates but still possible |
| 400-600°F | Low | Hot process lines | Low | Optional | Water driven off quickly when present |
| >600°F | Minimal | Very hot service | Low | Usually not feasible | Inspection focused on external damage/erosion |
| Cyclic / Intermittent | HIGH | Batch operations, shutdown/startup | HIGH | Yes — cyclic-rated coating | Repeated wet/dry cycles accelerate CUI |
| CUI Inspection Methods | |||||
| Method | Insulation Removal? | Detection | Cost | Speed | Best For |
| Visual with insulation removal | Yes (total) | All corrosion visible | High | Slow | Confirmed CUI, damage characterization |
| Visual with windowing | Yes (local) | At specific ports | Medium | Medium | Spot checks, RBI priority areas |
| Pulsed Eddy Current (PEC) | No | General wall loss under insulation | Medium | Medium-Fast | Screening long runs without removal |
| Radiography (DR or CR) | No | Wall loss, weld issues | High | Slow | Specific locations, welds, nozzles |
| Profile Radiography | No | Real-time thickness | High | Fast | Pipe supports, complex geometries |
| Thermal Imaging (IR) | No | Wet insulation detection | Low | Fast | Finding wet areas indicating ingress |
| Ultrasonic (after removal) | Yes | Precise thickness measurement | Low (after removal) | Fast | Detail sizing of known damage |
| Source: API 583 (CUI), API 581 (RBI), CUI_Inspection_Guide_v1.xlsx, IPE-EP-11 series (Refractory, Insulation, Fireproofing) |
Source: Materials_and_Corrosion_Curriculum_v1.xlsx · Sheet: Mod 7 - CUI Prevention
© 2026 Inflection Point Engineering, LLC. All rights reserved. The content of this page — including calculation methods, reference data, written analysis, interactive tools, and source code — is the intellectual property of Inflection Point Engineering, LLC and is protected under applicable copyright, trademark, and trade secret laws. Unauthorized reproduction, redistribution, modification, or derivative use in whole or in part is prohibited without prior written consent.
Disclaimer. This material is provided for informational and educational purposes only and does not constitute professional engineering advice. Calculations, reference data, and methodologies are based on published standards and accepted engineering practice but are not a substitute for engineering judgment, site-specific analysis, or review by a licensed Professional Engineer. Inflection Point Engineering, LLC makes no warranties, express or implied, regarding the accuracy, completeness, or fitness for a particular purpose of any content presented here, and shall not be liable for any direct, indirect, incidental, or consequential damages arising from its use. Users assume all risk associated with applying this content to real-world design, operations, or decisions.