Inspection and NDE Curriculum
Module from the Inspection and NDE Curriculum curriculum.
Module 9 - Fitness-for-Service (API 579-1) · Learning Objectives · 1. Distinguish Level 1 (screening) / Level 2 (standard) / Level 3 (detailed FEA/FMD) · 2. Apply Level 1 for LTA using Part 4 procedures · 3. Apply Level 1 for pitting (Part 6), blisters (Part 7), dents (Part 8) · 4. Apply Level 2 for crack-like flaws (Part 9) using FAD · 5. Evaluate creep (Part 10), brittle fracture (Part 3), fatigue (Part 14) · API 579 Part Overview
| Part | Subject | Damage Type | Level Types | Notes | Use |
|---|---|---|---|---|---|
| Part 3 | Brittle fracture | Low-temperature service | 1, 2, 3 | Charpy, MAT | Cold service |
| Part 4 | Local thin area (LTA) | General or local corrosion | 1, 2 | Very common | Piping + vessel |
| Part 5 | Pitting | Local attack | 1, 2 | Per pit depth | CS/alloy |
| Part 6 | Blisters + HIC | Hydrogen-induced | 1, 2 | Wet H2S | Sour |
| Part 7 | Creep | Creep damage | 1, 2, 3 | Remaining creep life | Hot service |
| Part 8 | Fire damage | Post-fire | 1, 2 | Charpy retest | After fire |
| Part 9 | Crack-like flaws | Cracks | 2, 3 | FAD | Piping girth |
| Part 10 | Creep remaining life | Creep | 1, 2, 3 | Life frac | Long-term |
| Part 11 | Fatigue | Cyclic | 1, 2, 3 | S-N curve | Cyclic service |
| Part 12 | Dent + gouge | Mechanical damage | 1, 2 | Depth, strain | Piping |
Source: Inspection_NDE_Curriculum_v1.xlsx · Sheet: FFS
© 2026 Inflection Point Engineering, LLC. All rights reserved. The content of this page — including calculation methods, reference data, written analysis, interactive tools, and source code — is the intellectual property of Inflection Point Engineering, LLC and is protected under applicable copyright, trademark, and trade secret laws. Unauthorized reproduction, redistribution, modification, or derivative use in whole or in part is prohibited without prior written consent.
Disclaimer. This material is provided for informational and educational purposes only and does not constitute professional engineering advice. Calculations, reference data, and methodologies are based on published standards and accepted engineering practice but are not a substitute for engineering judgment, site-specific analysis, or review by a licensed Professional Engineer. Inflection Point Engineering, LLC makes no warranties, express or implied, regarding the accuracy, completeness, or fitness for a particular purpose of any content presented here, and shall not be liable for any direct, indirect, incidental, or consequential damages arising from its use. Users assume all risk associated with applying this content to real-world design, operations, or decisions.
© 2026 Inflection Point Engineering, LLC. All rights reserved.